›PV Series High-Low Temperature and Temperature/Humidity Test Chambers. Custom sizes and configurations available.
Suitable for the following test standards: Humidity Freeze Test +85°C ± 2°C , 85% ± 5% RH / -40°C ± 3°C To determine the ability of the module to withstand the effects of high temperature and humidity followed by sub-zero temperatures. IEC61215, 10.12 (JIS C-8990) IEC61646, 10.12 (JIS C-8991) Thermal Cycling Test -40°C / +90°C To make an assessment of the module's ability to withstand exposure to several environmental conditions during transportation and/or storage. JIS C-8917 JIS C-8938 -40°C / +85°C To make an assessment of the module's ability to withstand exposure to several environmental conditions during transportation and/or storage. IEC61215, 10.11 (JIS C-8990) IEC61646, 10.11 (JIS C-8991)
Damp Heat Test +85°C ± 2°C , 85% ± 5% RH To evaluate the ability of the module for use and/or storage under high temperature and humidity. IEC60068-2-78 (JID C-8917, C-8938, C-60068-2-3) To determine the ability of the module to withstand the effects of long-term penetration of humidity. IEC61215, 10.13 (JIS C-8990) IEC61646, 10.13 (JIS C-8991) Temperature/Humidity Cycling Test +85°C ± 2°C , 85% ± 5% RH / -40°C ± 3°C To determine the deterioration level for use and/or storage in short time under condition of temperature change in high relative humidity. JIS C-8917 JIS C-8638 Low Temperature Sub-Cycle Test +65°C ± 2°C , 93% ± 3% RH /+25°C ± 2°C , 80-96% RH / -10°C ± 3°C IEC60068-2-38, 6.3.1 (JIS C-8962) Temperature Test +85°C ± 2°C To evaluate the ability of the module for use and/or storage under high temperature IEC60068-2-2, (JIS C-8917, C-60068-2-2) IEC60068-2-2, (JIS C-8938, C-60068-2-2)
|
 |
›FS Series Standard Design, High Performance Pre-engineered Temperature & Temperature/Humidity Chambers. Refrigeration system features advanced compressor technology, multi-voltage transformers, dramatically increased airflow and superior gradients. Available in 600, 1200, and 1800 Liter models.
Suitable for the following test standards: Thermal Cycling Test -40°C / +90°C To make an assessment of the module's ability to withstand exposure to several environmental conditions during transportation and/or storage. JIS C-8917 JIS C-8938 -40°C / +85°C To make an assessment of the module's ability to withstand exposure to several environmental conditions during transportation and/or storage. IEC61215, 10.11 (JIS C-8990) IEC61646, 10.11 (JIS C-8991) Temperature/Humidity Cycling Test +85°C ± 2°C , 85% ± 5% RH / -40°C ± 3°C To determine the deterioration level for use and/or storage in short time under condition of temperature change in high relative humidity. JIS C-8917 JIS C-8638 Low Temperature Sub-Cycle Test +65°C ± 2°C , 93% ± 3% RH /+25°C ± 2°C , 80-96% RH / -10°C ± 3°C IEC60068-2-38, 6.3.1 (JIS C-8962) Temperature Test +85°C ± 2°C To evaluate the ability of the module for use and/or storage under high temperature IEC60068-2-2, (JIS C-8917, C-60068-2-2) IEC60068-2-2, (JIS C-8938, C-60068-2-2)
|
|
|
|
|
 |
›EnviroFLX Series Standard Pre-engineered Temperature & Temperature/Humidity Chambers. Refrigeration system features scroll compressors capable of achieving -40°C in single stage configuration. Available in 300, 500, and 900 Liter models.
Suitable for the following test standards: Thermal Cycling Test -40°C / +90°C To make an assessment of the module's ability to withstand exposure to several environmental conditions during transportation and/or storage. JIS C-8917 JIS C-8938 -40°C / +85°C To make an assessment of the module's ability to withstand exposure to several environmental conditions during transportation and/or storage. IEC61215, 10.11 (JIS C-8990) IEC61646, 10.11 (JIS C-8991) Temperature/Humidity Cycling Test +85°C ± 2°C , 85% ± 5% RH / -40°C ± 3°C To determine the deterioration level for use and/or storage in short time under condition of temperature change in high relative humidity. JIS C-8917 JIS C-8638 Low Temperature Sub-Cycle Test +65°C ± 2°C , 93% ± 3% RH /+25°C ± 2°C , 80-96% RH / -10°C ± 3°C IEC60068-2-38, 6.3.1 (JIS C-8962) Temperature Test +85°C ± 2°C To evaluate the ability of the module for use and/or storage under high temperature IEC60068-2-2, (JIS C-8917, C-60068-2-2) IEC60068-2-2, (JIS C-8938, C-60068-2-2)
|
 |
›WW Series Solid Construction Walk-in/Drive-in Temperature and Temperature/Humidity Test Rooms. Custom sizes and configurations available.
Suitable for the following test standards:
Humidity Freeze Test +85°C ± 2°C , 85% ± 5% RH / -40°C ± 3°C To determine the ability of the module to withstand the effects of high temperature and humidity followed by sub-zero temperatures. IEC61215, 10.12 (JIS C-8990) IEC61646, 10.12 (JIS C-8991) Thermal Cycling Test -40°C / +90°C To make an assessment of the module's ability to withstand exposure to several environmental conditions during transportation and/or storage. JIS C-8917 JIS C-8938 -40°C / +85°C To make an assessment of the module's ability to withstand exposure to several environmental conditions during transportation and/or storage. IEC61215, 10.11 (JIS C-8990) IEC61646, 10.11 (JIS C-8991)
Damp Heat Test +85°C ± 2°C , 85% ± 5% RH To evaluate the ability of the module for use and/or storage under high temperature and humidity. IEC60068-2-78 (JID C-8917, C-8938, C-60068-2-3) To determine the ability of the module to withstand the effects of long-term penetration of humidity. IEC61215, 10.13 (JIS C-8990) IEC61646, 10.13 (JIS C-8991) Temperature/Humidity Cycling Test +85°C ± 2°C , 85% ± 5% RH / -40°C ± 3°C To determine the deterioration level for use and/or storage in short time under condition of temperature change in high relative humidity. JIS C-8917 JIS C-8638 Low Temperature Sub-Cycle Test +65°C ± 2°C , 93% ± 3% RH /+25°C ± 2°C , 80-96% RH / -10°C ± 3°C IEC60068-2-38, 6.3.1 (JIS C-8962) Temperature Test +85°C ± 2°C To evaluate the ability of the module for use and/or storage under high temperature IEC60068-2-2, (JIS C-8917, C-60068-2-2) IEC60068-2-2, (JIS C-8938, C-60068-2-2)
|