»Main Control Screen
- Touch screen commands
- Independent Fuzzy Logic Parameters
- Data Input Via Pop-up Displays
- Set Point Versus Process Variable Displays
- 12 Event/Auxiliary Outputs
- Selectable Inputs, T/C, RTD, Voltage, Current
- Selectable Restart Modes After Power Failure
- Quick Draw for Optimized Performance
- Complete Diagnostics
- Battery Backup
- Optional Data Logging Capabilities up to 10 Channels
|

»Predictive Care Screen
- System operating pressures and temperatures are displayed and compared to predict possible system faults
- Shows tabulated readings for key pressures and temperatures
- Historical performance data can be retrieved and plotted to show operating trends
- Recommended high/low limits and current operating values of the system are displayed
- Abnormal readings are highlighted in red to indicate a potential problem
›Return to top of page
|

»Graphics and Profile Screens
- Visual profile allows user to easily confirm entered data
- Real time graphics display of process variables
- Profiles can be stored for future retrieval and display
|
|

»Maintenance Counter Reset Screen
- Allows technician to easily reset an individual counter after the component has been replaced
- Actual usage time can be accurately maintained
|

»System Performance Screen
- Get a visual display summary of system operation
- Caution signals activate this early warning system allowing for problem detection prior to having a system shut down
|

»Logging Screen
- Logging intervals and destination locations can be selected as well as access to the log files
- Data to be logged can also be selected
|
|

»Edit Program Screen
- Allows set points and event relays to be defined
- Enter step time, the next step and any repeats
- Profile looping and nested looping
- Cut, paste, insert, and delete steps to reduce programming time
|

»Program Setup Screen
- Select the program to be run
- Define program start segment
- define program start/stop times
- Make selections for power failure mode operation
|

»Program Management Screen
- Easily select options for creating, editing, storing, or retrieving program information
|
|

»Start/Stop Menu Screen
- Stop the system
- Star the program
- Enter program setup mode
|

»Refrigeration System Screen
- Easy to read pictorial view of your system's critical operating pressures and temperatures
- Eliminated the need to connect manifold gauges when verifying system performance
|

»Fuzzy Configuration Screen
- Reduces costly parameter tuning by eliminating the need for traditional P.I.D. tuning constants
- 5 independent fuzzy logic output settings allow the computer to fine-tune all chamber control functions
|
|

»Quick Draw Screen
- Allows operator to program in air temperature set point overshoots while not damaging the product
- Allows the system to use all of its capacity without "throttling back" as set points are approached
|

»Password Configuration Screen
- Provides qualified technicians with the ability to prevent unauthorized access into key setup modes
- 4 password levels allow entry to simple program areas without compromising security to vital configuration modes
|

»Alarm Screen
- Simplifies system diagnostics
- All major system faults, acknowledgements, and returns to normal status are time/date stamped to show recent history of system failures
|
|

»Manual Set Point Screen
- For simple set point operation
- Select channel, enter set points, and press commit
- System will automatically control at specified conditions
|

»Maintenance Screen
- Eliminates guesswork when calculating run times on the system's compressor, heater, or blower motors
- Displays actual hours of operation for each
- Includes recommended maintenance for solenoids and counts every cycle of operation for comparison against its designed lifespan
|

»Program Filename Screen
- 16 digit alphanumeric display
- Allows for recognizable filenames for any given program
- Eliminates future confusion between programs
|
|
Would you like to print a data sheet for this equipment?

›Click here for downloadable Solutions Plus(tm) Literature
|
»General Operating Specifications:
- Ambient Temperature - 0 to 55°C
- Ambient Humidity - 35 to 85% RH (non-condensing)
- Voltage - 120 VAC ± 10% 50/60 Hz
»Output Specifications:
- Resistive Load - 2 A/pt. 8 A/4 pts.
- Load Voltage - 250 VAC or 30 VDC (surge diode required)
- Other loads - 80 VA (inductive) 100 W (lamp)
- Isolation - Mechanical
Please direct any inquiries to:
›sales@envirotronics.com
›Click here to return to the Solutions Plus intro page
›Return to top of page
|
Would you like to download the Solutions Plus Operator's Manual?

›Click here to download the Solutions Plus(tm) Manual
Viewing and printing PDF files will require Adobe® Acrobat® Reader. Adobe® Acrobat® Reader is available for free download at:

|