Guaranteed part temperature recovery/soak monitors the worst case part thermocouple and allows transfer only when set-point temperature has been reached
Thermal heat sinks in each zone for peak demand of heating and cooling. Provides extra thermal energy to efficiently meet the MIL-STD 883C requirements.
Temperature recorder provides 24 hour part temperature recording as the load travels from zone to zone.
Environmentally correct refrigerants are used that are ozone-free and meet all current regulatory requirements.
Safety:
- Electrically interlocking chamber doors and equipment section doors
- Electromechanical carrier lockout
- Transfer alarm/jam alarm
- Factory set over temperature controls
- Basket automatically stops when doors are opened
- Emergency Off Button (optional)
Full opening access doors and removable access panels with quick release hardware for ease in servicing
Adjustable door latch(es)
Nichrome wire heating elements with failsafe fusible link
Air circulation system has solid stainless steel jackshafts
Solid state heat switching
1-inch travelling access port
Pneumatically operated elevator transfer system
Two adjustable shelves in carrier basket
Main power disconnect switch
Door safety limit switches